Radiation tests of real-sized prototype RPCs for the Phase-2 Upgrade of the CMS Muon System
Yazarlar (101)
KS Lee
SW Cho
SY Choi
Beixue Hong
Yunsun Go
MH Kang
JH Lim
SK Park
Anna Cimmino
Shannon Crucy
Alexis Fagot
Muhammad Gul
AAO Rios
Michael Tytgat
Nikolaos Zaganidis
Soher Aly
Yasser Assran
Amr Radi
A Sayed
G Singh
M Abbrescia
G Iaselli
M Maggi
G Pugliese
Piet Verwilligen
W van Doninck
S Colafranceschi
A Sharma
L Benussi
S Bianco
D Piccolo
F Primavera
V Bhatnagar
R Kumarl
A Metha
J Singh
A Ahmad
M Ahmad
W Ahmed
MI Asghar
IM Awan
H Hoorani
WA Khan
T Khurshid
S Muhammad
MA Shah
H Shahzad
MS Kim
M Goutzvitz
G Grenier
F Lagarde
IB Laktineh
S Carpinteyro Bernardino
C Uribe Estrada
I Pedraza
CB Severiano
S Carrillo Moreno
F Vazquez Valencia
LM Pant
S Buontempo
N Cavallo
M Esposito
F Fabozzi
G Lanza
L Lista
S Meola
M Merola
I Orso
P Paolucci
Filip Thyssen
A Braghieri
A Magnani
P Montagna
C Riccardi
P Salvini
Ilaria Vai
P Vitulo
Y Ban
SJ Qian
M Choi
Y Choi
J Goh
D Kim
A Aleksandrov
R Hadjiiska
P Iaydjiev
M Rodozov
S Stoykova
G Sultanov
M Vutova
A Dimitrov
L Litov
B Pavlov
P Petkov
D Lomidze
C Avila
A Cabrera
JC Sanabria
I Crotty
J Vaitkus
Makale Türü Özgün Makale (SSCI, AHCI, SCI, SCI-Exp dergilerinde yayınlanan tam makale)
Dergi Adı Journal of Instrumentation (Q2)
Makale Dili Basım Tarihi 08-2016
Cilt / Sayı / Sayfa 11 / 8 / – DOI 10.1088/1748-0221/11/08/C08008/meta
Makale Linki https://iopscience.iop.org/article/10.1088/1748-0221/11/08/C08008/meta
UAK Araştırma Alanları
Nükleer Fizik
Özet
We report on a systematic study of double-gap and four-gap phenolic resistive plate chambers (RPCs) for the Phase-2 upgrade of the CMS muon system at high η. In the present study, we constructed real-sized double-gap and four-gap RPCs with gap thicknesses of 1.6 and 0.8 mm, respectively, with 2-mm-thick phenolic high-pressure-laminated (HPL) plates. We examined the prototype RPCs with cosmic rays and with 100-GeV muons provided by the SPS H4 beam line at CERN. To examine the rate capability of the prototype RPCs both at Korea University and at the CERN GIF++ facility, the chambers were irradiated with 137Cs sources providing maximum gamma rates of about 1.5 kHz cm−2. For the 1.6-mm-thick double-gap RPCs, we found the relatively high threshold on the produced detector charge was conducive to effectively suppressing the rapid increase of strip cluster sizes of muon hits …