Energy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at √s=7 TeV
Yazarlar (1)
Makale Türü Açık Erişim Özgün Makale (SSCI, AHCI, SCI, SCI-Exp dergilerinde yayınlanan tam makale)
Dergi Adı Journal of Instrumentation (Q1)
Dergi ISSN 1748-0221 Dergi Bilgileri (2013)
Makale Dili İngilizce Basım Tarihi 09-2013
Cilt / Sayı / Sayfa 8 / 9 / – DOI 10.1088/1748-0221/8/09/P09009
Makale Linki https://scholar.google.com/scholar?cluster=5159762823590037061&hl=en&oi=scholarr
UAK Araştırma Alanları
Fen Bilimleri ve Matematik
Özet
The energy calibration and resolution of the electromagnetic calorimeter (ECAL) of the CMS detector have been determined using proton-proton collision data from LHC operation in 2010 and 2011 at a centre-of-mass energy of √s = 7 TeV with integrated luminosities of about 5fb-1. Crucial aspects of detector operation, such as the environmental stability, alignment, and synchronization, are presented. The in-situ calibration procedures are discussed in detail and include the maintenance of the calibration in the challenging radiation environment inside the CMS detector. The energy resolution for electrons from Z-boson decays is better than 2% in the central region of the ECAL barrel (for pseudorapidity |η| <
Anahtar Kelimeler
Calorimeters | Gamma detectors (scintillators, CZT, HPG, HgI etc) | Large detector systems for particle and astroparticle physics
BM Sürdürülebilir Kalkınma Amaçları
Atıf Sayıları
Web of Science 145
Scopus 143
Energy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at √s=7 TeV